1. Fit the installation plate horizontally
on structural parts of the wall with
spaces around the installation plate.
2. If the wall is made of brick, concrete
or the like, drill five or eight 0.2 inch
diameter holes in the wall. Insert Clip
anchor for appropriate mounting screws.
3. Fit the installation plate on the wall
with five or eight type A screws.
Mount the Installation Plate and drill
holes in the wall according to the
wall structure and corresponding
mounting points on the installation
plate. The installation plate provided
with the machine differ from appliance
to appliance.
(Dimensions are in inch unless
otherwise stated).
1. Determine hole positions according to left and right
side of the installation plate. The hole center is obtained
by measuring the distance as shown in the diagram above.
2. Dirll the piping plate hole with 2.5 inch hole-core drill.
3. Drill the piping hole at either the right or the left and the
hole should be slightly slanted to the outdoor side.
4. Always take steps to protect the pipe when drilling metal
grid, metal plate or the like.
INSTALLATION MANUAL FOR ROOM AIR CONDITIONER
(Split Wall-Mounted Type)
DRILL A HOLE IN THE WALL
INSTALLATION PLATE MOUNTING
2
NOTE:
NOTE:
Installation Plate Mounting
1
The mounting wall is strong and solid
enough to prevent it from the vibration.
" "
"
"
I
N
D
O
O
R
U
N
I
T
Right rear side
refrigerant pipe
hole 2.6
Right rear side
refrigerant pipe
hole 2.6
Right rear side
refrigerant pipe
hole 2.6
Left rear side
refrigerant
pipe hole 2.6
Left rear side
refrigerant
pipe hole 2.6
Left rear side
refrigerant
pipe hole 2.6
6inch or more to ceiling
Indoor unit outline
Indoor unit outline
Indoor unit outline
4.8inch or
more to wall
4.8inch or
more to wall
Correct orientation
of Installation Plate
Except the above parts provided, the other parts needed during installation you must
purchase.
ACCESSORIES
NOTE:
6inch or more to ceiling
4.8 inch or
more to wall
4.8inch or
more to wall
SELECT THE BEST LOCATION
Please read these safety precautions carefully before installation
Be sure to follow all the precautions below, they are all important for ensuring safety.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to property.
SAFETY PRECAUTIONS
CAUTION
WARNING
Please read this installation manual carefully before operating the unit to ensure correct installation.
Installation must be performed in accordance with the requirement of NEC and CEC by authorized
personnel only.
Contact an authorized service technician for repair, maintenance and installation of this unit.
This appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by persons responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
All the pictures in the instructions are for explanation purposes only. The actual shape should prevail.
The design and specifications are subject to change without prior notice for product improvement.
Consult with the sales agency or manufacturer for details.
There should not be any heat source or stream
near the unit.
There should not be any obstacles blocking the
air circulation.
A place where air circulation in the room is good.
A place where drainage can be easily done.
A place where noise prevention is taken into
consideration.
Do not install the unit near the doorway.
Ensure the spaces indicated by arrows from the
wall, ceiling, fence or other obstacles.
There should not be any direct sunlight. If unavoidable,
sunlight prevention should be taken into consideration.
Outdoor unit
dimension
inch(WxHxD)
A(inch)
18.1
B(inch)
9.9
20.9
11.5
21.6 10.9
Mounting dimensions
27.6 x 21.3 x 9.5
30.8 x 21.3 x 9.9
30 x 23.3 x 11.3
Indoor unit
Outdoor unit
If an awning is built over the unit to prevent
direct sunlight or rain, be careful that heat
radiation from the condenser is not obstructed.
There should not be any animal or plant which
could be affected by hot air discharged.
Keep the spaces indicated by arrow from wall
ceiling, fence or other obstacles.
Do not place any obstacles which may cause
a short circuit of the discharged air.
Settlement of outdoor unit
A
W
B
D
Air inlet
Air outlet
Air inlet
INSTALLATION PRECAUTIONS
CONNECT THE CABLE TO THE INDOOR UNIT
3
The cable size and the current of the fuse
or switch are determined by the maximum
current indicated on the nameplate which
is located on the side panel of the unit.
Please refer to the nameplate before
selecting the cable, fuse and switch.
Terminal block of indoor unit
Connect the cable to the indoor unit
NOTE:
Before performing any electrical work, turn off the power at the main panel to the unit.
1. The inside and outside connecting cable can be connected without removing the front grill.
2. Lift the indoor unit panel up, remove the electrical box cover by loosening the screw.
3. Ensure the color of wires of outdoor unit and the terminal Nos. are the same to the indoor units
respectively.
4. Wrap those cables not connected with terminals with insulation tapes, so that they will not touch
any electrical components. Secure the cable onto the control board with the cord clamp.
NOTE:
Electrical box
cover
Front Panel
1.44
9000Btu/h models(A:26.8, B:10.1, C:6.7, D:3.7)
12000Btu/h models(A:30.3, B:10.1, C:6.7, D:3.7)
18000Btu/h models(A:35.6, B:10.8, C:3.2, D:4)
A
A
A
C
C
C
D
D
D
B
B
B
6inch or more to ceiling
4.8inch or
more to wall
4.8inch or
more to wall
To outdoor unit
To outdoor unit
Cord clamp
1
2
3
4
5
7
8
9
10
6
Installation Plate
Clip Anchor
Self-tapping Screw A ST3.9x25
Seal (For cooling & heating models only)
Drain Joint (For cooling & heating models only
Connecting
pipe
Assembly
Liquid side
Gas side
Remote control
Air freshening filter (installed on Air filter)
Self-tapping Screw B ST2.9x10
Parts you must purchase. The pipe
size differs from appliance to appliance.
Consult the technician for the proper
size.
1
5-8(depending on models)
5-8(depending on models)
1
1
1
2
1
1
Remote control holder
Number
Name of Accessories
Qty
optional
parts
4
CONNECTIVE PIPE AND DRAINAGE INSTALLATION
1. Run the drain hose sloping downward.
Do not install the drain hose as illustrated
in wrong figures.
2. When connecting extension drain hose,
insulate the connecting part of extension
drain hose with a shield pipe, do not let
the drain hose slack.
Drainage
Right
Wrong
L1 L2 S
L1 L2 S
or
Suggest Minimum Wire Size
(AWG: ):American Wire Gage
Appliance Amps
AWG Wire Size
10
13
18
25
18
16
14
12
30
10
2020323B3338
Electrical work
(6 in)
(4.8in)
(4.8in)
(7.55ft)
(11.9in)
(23.7in)
(11.9in)
(23.7in)
(6.57ft)
(0.2-0.3inch)
Electric safety regulations for the initial Installation
1. If there is any safety concerns with the electrical power supply the technician should consult a
certified electrician and have the problem resolved before installing the unit.
2. Power voltage should be in the range of 90%~110% of rated voltage.
3. The circuit breaker at the electrical panel should be no more than 1.5 times the max current of the
outdoor unit. All the electrical information is located on the reverse side of the electrical cover on the
on the outdoor unit. Follow all local and national electric codes.
4. Each outdoor unit must have its own circuit breaker.
5. Install the proper sized electrical wire from the circuit breaker located at the electrical panel to an
outdoor weather proof disconnect.
6. The outdoor unit must be grounded per code. If the unit is not grounded it will not operate per
system specifications.
7. Install a liquid tight electrical whip from the outdoor disconnect to the outdoor unit.
8. All wiring must comply with local and national codes and be installed by a certified electrician.
CAUTION
WARNING
1) Install according to these installation instructions. If installation is defective, it will cause water
leakage, electrical shock, or fire.
2) It will cause the unit to fall, have water leakage, give an electrical shock and/or cause a fire.
3) Install the indoor unit per these instructions. Make sure it is secured properly to the wall. If not
installed properly the unit could drop or fall causing injury.
4) An independent circuit breaker must be used for each indoor unit. If the circuit breaker is not sized
properly, it will cause an electrical shock and/or a fire.
5) Use the specified cable and connect properly to the terminals. If the cable is not connected
properly, it will cause a hot spot or fire at the connection.
6)
Wiring routing must be properly arranged so that control board cover is fixed properly. If control board
cover is not fixed properly, it will overheat at connection point of terminal, fire or electrical shock.
7) When connecting the refrigerant piping, make sure no debris or foreign matter gets into the
refrigerant piping.
1) This equipment must be grounded properly. Follow the local and national codes when choosing the
proper outdoor electrical disconnect. The unit will not run properly and could cause an electrical
shock if not installed properly.
2) Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and
accumulates at surrounding of the unit, it may cause fire.
3) Install condensate drain pipe as mentioned in the installation instructions. If drain is not installed
properly, water could back up in the system causing water damage.
The outdoor unit should be installed on a concrete or
plastic pad or mounted to a wall with the proper brackets
and secured per local and national codes.
NOTE: The outdoor unit you purchase may be like one
of the following. Install the outdoor unit according to the
dimension as indicated in the table below:
1/4(6.35mm)
3/8 (9.52mm)
3/8 (9.52mm)
5/8 (16mm)
1/2 (12.7mm)
Page view 0
1 2

Summary of Contents

Page 1 - DRILL A HOLE IN THE WALL

1. Fit the installation plate horizontally on structural parts of the wall with spaces around the installation plate.2. If the wall is made of

Page 2 - REFRIGERANT PIPE CONNECTION

Install the outdoor unit on a rigid base to prevent increasing noise level and vibration.Determine the air outlet direction where the discharged air i